n E1 interface
Supports automatic removal and recovery of E1 channels that used for carrying payload. The E1 channels that have urgent alarm, such as LOS and LOF, or the Bit Error Rate (BER) exceeds 1E-6, are removed automatically, and during this period, some Ethernet packets may be lost; It will be resumed when the fault dismisses .
Supports the embedded E1 BER Tester function, to detect any E1 channel of 4 channels. When the embedded E1 BER Tester is used via CLI command, the particular E1 channel on testing mode can not convey E1 service, while the other E1 channels are not affected by the BER test.
The differential delay between any two of the 4 E1 can be up to 220ms; when the factual differential delay exceeds 220ms, alarm is generated and Ethernet is cut off.
Jitter tolerance and jitter transfer characteristic compliant to ITU-T G.823.
n Ethernet interface
Provides up to 4 shared Ethernet interfaces.
1024 MAC address table and 5-minute aging time.
Accepts frames with length between 64 and 1916 bytes (otherwise filtering).
VLAN function based on tags compliant to IEE 802.1Q.
Throughout statistic of the Ethernet packets based on port, such as error packets.
Configurable pause flow control .
Optional optical Ethernet interface compliant to IEEE 802.3u 100BASE-FX standard (can communicate with remote optical transceiver) and electrical Ethernet interface compliant to IEEE 802.3u 100 BASE-TX standard.
n Management interface
n Timing mode
Optional local timing mode and tracing E1 line (set by GUI).
The source of tracing E1 line can be switched according to the signal quality. For instance, the system is set as tracing the first E1 link, when some malfunction occurs to it (i.e., urgent alarm LOS/AIS/LOF/LOMF or the signal is looped back), the system will automatically change to tracing the second E1 link; when the fault disappear, the system will be re-tracing the first E1 link.
n Compliant to ITU-T standards
GFP-F encapsulation recommendation G.7041.
Virtual concatenation(VCAT) and Link Capacity Adjustment Scheme (LCAS) recommendation G.7042.
Ethernet to nxE1 mapping recommendation G.7043.
Ethernet to single E1 mapping recommendation G.8040.
n Bandwidth is increased without damaging the Ethernet data, and can be decreased no injury through management.
n The E1s in the local and remote sides can be arranged arbitrarily, such as, the remote E1 port 1 can communicate with local E1 port 3.
n Supports bandwidth unbalanced usage ?when some E1s cannot work properly (i.e. the bandwidth of the sending and receiving can be 2E1 and 3E1 respectively ).
n Provides the E1 connection-ship between local and remote system (accessed via GUI).
n E1 tributary signal loopback automatic detect and cut off; when some E1 signal is detected as looped back, it will be not employed for carrying payload temporarily, and when the loopback is broken, this E1 will resume to be used.
n Remote/local E1 loopback function will be convenient for E1 line(transmission system included) testing .
n Complete alarm which is selectable to be shown between local and remote.
n support AC 220V power or DC 48V power or double AC+DC power
n Single-board design with small dimension, 1 U high and low power consumption.